Technical parameters
Reference standard | GB/T17702 IEC61071 |
Capacity range | 1 ~ 60μF |
Capacity deviation | ±5%(J) ±10%(K) |
Voltage range | 200v.ac ~ 600v.ac/400.dc~ 1200v.dc |
Interpole withstand voltage | 1.5Un/10s |
Overvoltage | 1.1Un(8h/24h) |
1.15Un(30min/24h) | |
1.2Un(5min/24h) | |
1.3Un(1min/24h) | |
dielectric loss angle | Tg Δ0≤0.0002 |
Insulation resistance | ≥ 5000s(20 °c ± 5 °c 100v.dc 60s) |
Current impact resistance | > 50V/μS |
CLIMATE CATEGORIES | 40/85/21 |
Operating temperature range | -40°C~85°C |
Storage temperature range | -40 °c ~ 85 °c |
Lead-out mode | Insert plate, copper nut, copper bolt |
Use Altitude | <4000m |
life expectancy | 100000h(s ≤70°C) |
Encapsulation form | Plastic case, black epoxy |